SW200 Technical Information
Application |
Interrupted Uninterrupted |
|
Thermal Current Rating |
250A |
400A |
Intermittent Current Rating: |
||
30% Duty |
455A |
730A |
40% Duty |
395A |
630A |
50% Duty |
355A |
565A |
60% Duty |
325A |
515A |
70% Duty |
300A |
480A |
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:(In accordance with UL583*) |
||
Blowouts |
1500A at 96V D.C. |
|
No Blowouts |
1500A at 48V D.C. |
|
Rated Fault Current Breaking Capacity (Icn) Resistive Load:(In accordance with UL508*) |
||
Blowouts |
600A at 96V D.C. |
|
No Blowouts |
600A at 60V D.C. |
|
Maximum Recommended Contact Voltages |
||
Blowouts |
96V |
96V |
No Blowouts |
48V |
60V |
Typical Voltage Drop per pole across New Contacts at 250A |
40mV |
|
|
||
Mechanical Durability |
> 5,000,000 Cycles |
|
Coil Voltage Available (Us) (Rectifier board required for A.C.) |
6 - 240V |